FFP2 Drager X-Plore Mask - No Valve
20 piece
Drager
3956034
Intended use: Protection against solid and liquid non-volatile particles.
Scope of protection as indicated by product documentation, technical standards and installed application rules.
Relevant standards: EN 149: 2001 (Filtering Face Pieces)
Construction: The particle filtering half mask X-plore 1520 FFP2 consists of several layers of nonwoven materials, partly with electrical charge.
Working principle: Particle filtration by combined electrically charged and mechanical filter media.
Particle filtration efficiency test aerosols: Minimum efficiency (EN 149): Sodium chloride: 94 %
Paraffin oil: 94 %
Gas filtration capacity: Not applicable
Laboratory test results
Breathing resistance: at 30 litres/min, constant flow max. 0, 7 mbar (EN 149)
Inhalation: at 95 litres/min, constant flow max. 2, 4 mbar (EN 149)
Breathing resistance:
Exhalation: at 160 litres/min, constant flow max. 3, 0 mbar (EN 149)
Dolomite clogging test: Passed.